Fujitsu Eternus DX100 S3 User Manual page 839

Fujitsu eternus cli user's guide
Hide thumbs Also See for Eternus DX100 S3:
Table of Contents

Advertisement

Appendix A Error Messages/Error Codes
A.1 Error Messages
Message
number
E0362
E0390
E0391
E0392
E0393
E0394
E0395
E0396
E0397
E0399
E5000
E5001
E5002
E5003
E5010
E5033
E5034
E5081
Log transmission of E-Mail notification and AIS connect cannot be enabled simultaneously.
The log transmission of the E-mail notification and AIS Connect cannot be enabled simultaneously.
Backup REC Path information does not exist.
A backup file does not exist in the system. This also means a path information file has not been set for
the system yet.
Round trip time measurement has failed.
Measuring the round trip time has failed for any reason. Confirm the environment between the ETERNUS
DX storage systems.
Unsupported path type.
Could not execute due to the path type. Confirm the path type by using the "show rec-path" command.
Syntax error in REC path information. (iSCSI parameter(s) do not match actual)
A syntax error occurred for the specified copy path information file. Check the iSCSI parameter and correct
the syntax.
Failed to access the server.
Access to the server failed.
The object cannot be operated.
The target object cannot be operated.
A part of SpinUp/Down failed.
Some of the spinup/spindown operations failed.
All SpinUp/Down failed.
All of the spinup/spindown operations failed.
Syntax error in REC path information.
A syntax error was detected in the specified REC path information file. Check the output line given in the
details of this message.
Parameter not supported.
The specified parameter is not supported. Check the parameter that was specified.
User authority to use the parameter is improper.
The specified parameter cannot be used with the current user privilege.
Authority of security is necessary for data decryption.
The data cannot be decrypted because the user does not have the required privilege.
The user authority to use the command is improper.
The specified command cannot be executed with the current user privilege.
The volume encryption is specified for SED disk.
Volume encryption cannot be performed for a RAID group that is configured with SEDs.
Cannot Warm Boot CFL.
The warm boot cannot be performed because a concurrent firmware update is currently being performed
for a controller.
Cannot Hard Boot CFL.
The hard boot cannot be performed because a concurrent firmware update is currently being performed
for a controller.
Abnormal pinned CBE error.
Formatting cannot be performed because Pin exists.
ETERNUS CLI User's Guide
Copyright 2014 FUJITSU LIMITED
Message
Countermeasure for the error
839
P2X0-1210-05ENZ0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents