Fujitsu Eternus DX100 S3 User Manual page 560

Fujitsu eternus cli user's guide
Hide thumbs Also See for Eternus DX100 S3:
Table of Contents

Advertisement

Chapter 5 System Settings and Display
5.2 Network Management > set event-notification
-severity
This parameter specifies the events that will trigger a notification and cannot be specified if
the preset function is specified. An operand name starting with "e-" indicates a severity "Error
level" event, "w-" indicates a severity "Warning level" event, and "i-" indicates a severity
"Information level event". One or more event types can be specified by separating them with a
comma (,).
Example: -severity error, w-warning-disk (Specify "error" and "w-warning-disk")
"-suppression disable-when-no-hs" indicates whether the specified event is notified or not
when there is no hot spare in the system. It can be specified when "e-broken-disk", "e-rebuild-
copyback-without-redundant", " e-redundant", "w-warning-disk", or "w-raid-degrade-event" is
specified.
error
All the Error level events are notified.
warning
All the Warning level events are notified.
information All the Information level events are notified.
e-parts-error
When modules other than disks are broken, error level events are notified. Host
sense, SNMP, E-mail, and syslog may be specified as the notice method.
e-disk-error When a disk is broken, error level events are notified. Host sense, SNMP, E-mail,
and syslog may be specified as the notice method.
e-temperature-error
When the sensor detects an error level temperature, error level events are
notified. Host sense, SNMP, E-mail, and syslog may be specified as the notice
method.
e-battery-life
When battery life expires, error level events are notified. Host sense, SNMP, E-
mail, and syslog may be specified as the notice method. (only for the ETERNUS
DX500 S3/DX600 S3)
e-rebuild-copyback-with-redundant
When rebuild/copyback occurs to a RAID group with redundancy, error level
events are notified. Only Host sense may be specified as the notice method. Any
notice method may be specified.
e-rebuild-copyback-without-redundant
When rebuild/copyback occurs to a RAID group without redundancy, error level
events are notified. Only Host sense may be specified as the notice method. Any
notice method may be specified.
e-complete-redundant-copy
When the redundant copy is complete, error level events are notified. Any notice
method may be specified.
e-complete-rebuild
When rebuild is finished, error level events are notified. Host sense, SNMP, e-
mail, and syslog may be specified as the notice method.
e-bad-data When bad data on a track occurs, error level events are notified. Host sense,
SNMP, e-mail, and syslog may be specified as the notice method.
e-pinned-data
When pinned data occurs or disappears, error level events are notified. Host
sense, SNMP, e-mail, and syslog may be specified as the notice method. Note
that, however, host sense is not used as the notification method when pinned
data disappears.
ETERNUS CLI User's Guide
Copyright 2014 FUJITSU LIMITED
560
P2X0-1210-05ENZ0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents