Chapter 3 Configuration Settings and Display
3.5 Host Interface Management > set iscsi-parameters
-connect-ip Optional. This parameter specifies a global address (including 6to4 addresses) or a unique
-ipv6-gateway
-tcp-port
-tcp-window-scale
local address in IPv6 format. To delete an IP address that is already set, specify ALL0 (an IP
address with all zero bits).
This parameter can be specified as a parameter for the multiple IP address setting.
Example: -connect-ip 2000:100::10:1:0:250
Example: -connect-ip ::
Example: -connect-ip auto
ip_address
Global address or unique local address in IPv6 format
auto
The global address or the unique local address is automatically set in IPv6 for-
mat.
Optional. This parameter specifies the gateway server address in IPv6 format. The types of IP
addresses that can be specified are global addresses (including 6to4 addresses), link local
addresses, and unique local addresses. To delete an IP address that is already set, specify ALL0
(an IP address with all zero bits).
This parameter can be specified as a parameter for the multiple IP address setting.
Example: -ipv6-gateway 10.1.0.250
Example: -ipv6-gateway 0::0
Example: -ipv6-gateway auto
ip_address
Global address
auto
The gateway IP address is automatically set in IPv6 format.
Optional. This parameter specifies TCP port number for iSCSI Target function. The default TCP
port number value is 3260. This parameter can be specified as a parameter for the multiple IP
address setting.
tcp_port_number
TCP port number (0 – 28671)
Optional. This parameter specifies the TCP window scale expansion.
This parameter can be specified as a parameter for the multiple IP address setting. This param-
eter cannot be specified for iSCSI-RA (host interfaces that are only used for connecting older
models).
tcp_window_scale
TCP window scale (0 – 14)
Note that expected performance may not be possible under a high I/O load when
"0" or "1" is specified. Even if "8" or more is specified for the value, the operation
is performed the same as when "7" is specified.