Key Status; E.7 Key Status - Fujitsu Eternus DX100 S3 User Manual

Fujitsu eternus cli user's guide
Hide thumbs Also See for Eternus DX100 S3:
Table of Contents

Advertisement

Appendix E Status List

E.7 Key Status

Copyback
Redundant Copy
Partially Exposed Rebuild
Exposed Rebuild
Exposed
Partially Exposed
No Disk Path
SED Locked
Broken
Unknown
E.7

Key Status

The meaning of each key status is described below.
Normal
Expiration
Not Acquired
Key Server Error
Network Error
Modifying
Status
Copyback from the hot spare disk to the new data disk is being performed in the
RAID group.
Redundant copy to the hot spare disk is being performed in the RAID group.
Rebuilding from the first failed data disk to the hot spare disk or to the replaced
disk is being performed in the RAID group.
This status is displayed only when the RAID type of the RAID group is "High
Reliability (RAID6)".
Two of the data disks for the RAID group have failed. Rebuilding from the first
failed data disk to the hot spare disk or to the replaced disk is being performed.
In addition, all the hot spare disks have already been used. As a result, the
second failed data disk is waiting for the hot spare disk to become available.
This status is displayed only when the RAID type of the RAID group is "High
Reliability (RAID6)".
The RAID group lost redundancy due to disk failure.
One of the disks that configure the RAID group has failed.
This status is displayed only when the type of the RAID group is "High Reliability
(RAID6)".
The RAID group is blocked.
The RAID group is blocked.
If an SED authentication key cannot be obtained from the key server, "SED
Locked" is displayed.
The RAID group is broken.
A status other than the ones listed above.
Status
A valid key is registered for the SEDs. The key is in normal state.
An expired key is registered in the SED.
The key has expired, but a new key can be obtained from the server.
The required key for starting key server management is not obtained.
The allocation of the Master server and the Slave server to the key group has
been deleted.
The network between the ETERNUS DX and the key server is in normal status, but
no SED key is stored in the key server.
The key cannot be obtained due to a network error between the ETERNUS DX and
the key server.
A RAID group in which the key is being modified exists in the key group.
"RAID group of which key is modifying" indicates the following conditions:
The key is being updated manually from GUI or CLI
The key is automatically being updated because it expired
Updating of the key stopped due to an error
SEDs are maintained while a network error occurs when the security level is
"Low"
ETERNUS CLI User's Guide
Copyright 2014 FUJITSU LIMITED
Description
Description
935
P2X0-1210-05ENZ0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents