Chapter 6 Information Settings and Display
6.3 Maintenance Information > show disk-error
show disk-error
This command displays the details of disk errors.
■
Syntax
show disk-error
■
Parameter
No parameters.
■
Output
E
Disk Location
Status
Port
Media Error Media error count
Drive Error
Drive-Recovered Error
SMART Error SMART event count
I/O Timeout I/O timeout count
Link Error
Check-Code Error
■
Example(s)
The following example displays the disk error information:
CLI> show disk-error
E Disk
Location
- --------------- ------------------------------ ------ ------- ------- --------------- ------- ------- ------- ----------
* CE-Disk#0
* CE-Disk#1
DE#4-Disk#0
An error sign (*). This shows that there are some errors for both ports.
Disk number
Disk status
Disk port number
Drive error count
Drive recovered error count
Link error count
Check code error count
Status
Rebuild/Copyback
Available(Predictive Failure)
Rebuild/Copyback
ETERNUS CLI User's Guide
Copyright 2014 FUJITSU LIMITED
Port
Media
Drive
Drive-Recovered SMART
Error
Error
Error
Port#0
0
0
Port#1
0
0
Port#0
2
0
Port#1
0
0
Port#0
0
0
Port#1
0
0
694
I/O
Link
Check-Code
Error
Timeout Error
Error
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
P2X0-1210-05ENZ0
0
1
0
0
0
0