10-399 Fuser Intake Fan Failure RAP

The Fuser Intake Fan Failed.
NOTE: This status code is stored in NVM location 772-018 and cannot be reset by Power Off/
On. To reset this code, enter Diagnostics and change the value in NVM location 772-018 Fuser
Intake Fan from "1" to "0".
Initial Actions
Refer to BSD 10.1 and 10.12 for the following procedure.
Check for the following:
Ensure that connectors
P/J413B
and
and Fuser Intake Fan.
and there are no obvious crimped or broken wires.
Procedure
Open the Front Door. Cheat the Interlock. Enter dC330 010-061 Fuser Intake Fan-High Speed.
Press Start. Press Stop. The Fuser Intake Fan switches from Low Speed to High Speed
and back to Low Speed.
Y
N
Press Stop. +24 VDC is measured between P/J413B-13 on the IOT Drive PWB and
GND.
Y
N
Replace the IOT Drive PWB
(PL
+24 VDC is measured between P/J413B-13 and P/J413B-14 on the IOT Drive PWB.
Y
N
Go to
Flag 3
and
Flag 4
on BSD 10.1 and check the harness for an open circuit. If
the Harness is good, replace the IOT Drive PWB
Approximately +2 VDC is measured between P/J413B-12 on the IOT Drive PWB and
GND.
Y
N
Go to
Flag 5
on BSD 10.1 and check the harness for an open circuit. If the Harness
is good, replace the Fuser Intake Fan
Replace the Fuser Intake Fan
(PL
10.1).
Less than +1.0 VDC is measured between P/J413B-11 on the IOT Driver and GND.
Y
N
Go to
Flag 6
on BSD 10.1 and check the harness for a short circuit. If the harness is good,
replace the Fuser Intake Fan
(PL
10.1). If the problem continues, replace the IOT Drive
PWB
(PL
9.2).
Replace the IOT Driver PWB
(PL
9.2).
Replace the Fuser Intake Fan
(PL
10.1). If the problem continues, replace the IOT Drive PWB
(PL
9.2).
Status Indicator RAPs
10-399 Fuser Intake Fan Failure RAP, 10-421 Fuser Oil
P/J283
are seated correctly on the IOT Drive PWB
9.2).
(PL
9.2).
(PL
10.1).

10-421 Fuser Oil Level RAP

The Oil Empty Sensor detected the Oil Near Empty Condition continuously for 5 seconds.
NOTE: The Oil Near Empty Condition occurs when the sensor detects that the oil is low
(approximately 40k prints have been printed). The machine issues a warning when it detects
Fuser Oil Near Empty. When another 2000 - 4000 prints are printed out without servicing the
Fuser Oil, the machine issues a stop message and then stops printing.
NOTE: Oil usage varies depending on the types of images and paper being used. 30 - 40k
prints per bottle is typical. However, when an oil metering system (Metering Blade, Donor Roll,
etc.) is in need of service, it can use oil at two to three times the normal rate.
Initial Actions
Refer to BSD 10.5 and 10.12 for the following procedure.
Perform the following:
1.
Open the Drawer.
2.
Remove the Oil Cartridge
Oil Cartridge.
3.
Close the Drawer.
4.
Switch the power Off and then On.
Procedure
NOTE: This RAP assumes that there is fuser oil in the bottle and therefore is not a cause of the
10-421 Fault Code.
Enter dC330 010-222 Oil Empty Sensor. Press Start. The Oil Empty Sensor status is H.
Y
N
Press Stop. There is +5 VDC between P/J413A-3 on the IOT Drive PWB and GND.
Y
N
Go to
Flag 1
on BSD 10.5 and check the harness for an open circuit. If the harness is
good, replace the IOT Drive PWB
There is +5 VDC between P/J413A-14 on the IOT Drive PWB and P/J44-7 on the
Distribution PWB.
Y
N
Replace the Distribution PWB
Go to
Flag 2
on BSD 10.5 and check the harness for an open circuit. If the harness is
good, replace the Oil Empty Sensor
Drive PWB
(PL
9.2).
Replace the IOT Drive PWB
(PL
1/05
2-176
manuals4you.com
manuals4you.com
(PL
8.1). Verify that there is oil in the bottle. If not, install a new
(PL
9.2).
(PL
9.3).
(PL
8.7). If the problem continues, replace the IOT
9.2).
DocuColor 12/DCCS50
Reissue

Advertisement

Table of Contents
loading

Table of Contents