2. Cell Station (CS)

2.1
General
Cell Station (CS) is used for the PHS system. The following shows the outer view of CS (BS31) as an example.
A maximum three Personal Stations (PS) can be simultaneously accessed to a CS.

Interface Circuit Cards:

The following CSINT circuit card can be used for connecting CS to the
CSINT Circuit Card
PA-8CSIE
2.2
Installation Procedure
STEP 1: Run the cables between CS and its modular block (jack), and between the modular blocks and the
MDF.
STEP 2: Install CSINT circuit card into a proper slot of PIR for connecting CS. For more information about
CSINT circuit card, refer to the Circuit Card Description. When the CS is connected to a vacant port
of the existing CSINT card, this step is not necessary.
STEP 3: Terminate the installation cables to the MDF and the modular blocks.
STEP 4: Check the terminal locations on the MDF. To identify the lead names and the lead's terminal locations,
refer to LT Connector Lead Accommodation of the circuit card in the Circuit Card Description.
STEP 5: Provide the necessary cross connection on the MDF referring to the following figures.
Cell Station
PS
CS
PS
2-Wired Cell Station
(U-Interface)
2W/4W
2W
VOL.2-13
Cell Station (CS)
PS
.
system
Remarks
U Interface