Restoring Config Data via TFTP
SYSTEM
PCPro
Note 1: PCPro and Telnet both can be perfomed by single Personal Computer.
<Data Assignment on TFTP Server>
If the name of the backup config file is not sysdata, rename it to "sysdata".
STEP 1
Put the file in the root folder of TFTP server, and then start the TFTP server program.
STEP 2
Permit read behavior of this folder. For more information, refer to the appropriate manual at-
STEP 3
tached to the TFTP server program.
<Data Assignment on PCPro>
To search for the LENS of the target Analog 2MC, use the IPAN command.
STEP 4
To make environment setting for Telnet, use the ATUD command.
STEP 5
- Specify the LENS, which is belonging to the target Analog 2MC.
- Specify a user ID and a password, which are required for logging in Analog 2MC via Telnet.
- Input any letter for USER LEVEL because Analog 2MC does not use USERLEVEL.
- For VALID TIME, input a total of time required for completing this procedures.
A user ID and a password are temporary ones for download; you can specify them as you like
Note:
After completing the above, click the Set button.
STEP 6
<Data Assignment on Telnet PC>
Start a command prompt and enter "telnet <Analog 2MC's IP Address>" to con-
STEP 7
nect Analog 2MC via Telnet.
(1) Make environment setting for TFTP.
TFTP Server
(2) Make environment setting for Telnet
IP Network
Note 1
Note 1
Telnet PC
Analog 2MC (Analog Media Converter)
Configdata
(4) Copy a config file (Backup File)
from TFTP server via TFTP
Analog 2MC
ON
PWR
LINE
(IP Address: 192.168.10.4)
VOL.2-75