To make environment setting for Telnet, use the ATUD command.
STEP 5
- Specify the LENS, which is belonging to the target Analog 2MC.
- Specify a user ID and a password, which are required for logging in Analog 2MC via Telnet.
- Input any letter for USER LEVEL because Analog 2MC does not use USERLEVEL.
- For VALID TIME, input a total of time required for completing this procedures.
A user ID and a password are temporary ones for download; you can specify them as you like
Note:
After completing the above, click the Set button.
STEP 6
<Data Assignment on Telnet PC>
Start a command prompt and enter "telnet <Analog 2MC's IP Address>" to con-
STEP 7
nect Analog 2MC via Telnet.
Log in to the target Analog 2MC by entering the userID and the password, which are set in the
STEP 8
AUTD command.
After a prompt (->) is displayed, enter "usrConsole".
STEP 9
After a prompt (2A-MC>) is displayed, enter "put configdata <TFTP's IP Ad-
STEP 10
dress>" to download configuration data to Analog 2MC.
Confirm that "successfully completed" is displayed in the command prompt, indicating the
STEP 11
upload to TFTP server is completed normally.
Exit the HyperTerminal by selecting [File] -> [Exit].
STEP 12
Analog 2MC (Analog Media Converter)
VOL.2-74