7.
Setting ToS of DRS session:
2A-MC>SET DRSTOS PRECEDENCE
PRECEDENCE (0-7)
DELAY (0/1)
: 0
THROUGHPUT (0/1)
RELIABILITY (0/1)
COST (0/1)
: 0
DRS TOS setting succeeded.(0xC0)
2A-MC>_
The result of data setting is shown in a 1-byte (hexadecimal) format in accordance with the setting dialog
Note:
followed by the prompt. The meaning of 1-byte data is shown below:
Prec
2A-MC>SET DRSTOS VALUE
TOS (00-FF)
: C0
DRS TOS setting succeeded. (0xC0)
2A-MC>_
To make this assignment effective, use the SAVE command, and restart before exiting the maintenance com-
Note:
mand.
: 6
: 0
: 0
D
T
R
C
Analog 2MC (Analog Media Converter)
Line 1: Enter sub command name PRECEDENCE to set the
parameters such as Delay, Throughput, Reliability, and
Cost. Specify the value to each parameter.
Line 2: Precedence: 0-7 (low-high) (default=6)
Line 3: Delay: 0/1=Normal (default)/Low Delay ON
Line 4: Throughput:
0/1=Normal (default)/High Throughput ON
Line 5: Reliability:
0/1=Normal (default)/High Reliability ON
Line 6: Cost: 0/1=Normal (default)/Cost Precedence ON
Line 7: Result is shown
Prec.=PRECEDENCE (3 bits)
D=Delay
T=Throughput
R=Reliability
C=Cost
Line 1: Enter the sub command name VALUE to set the DRS
setting value directly.
Line 2: Specify the value in the range of 00-FF (default=C0)
Line 3: Result is shown