Table 8.1 Function Description of Digital Input (DI)

Setting Value: 0x01
DI Name
SON
When this DI is On, servo is activated (Servo On)
Setting Value: 0x02
DI Name
ARST After the alarm has been cleared, when the DI is ON the
drive will show that the alarm has been cleared.
Setting Value: 0x03
DI Name
GAINUP In speed and position mode, when the DI is ON (P2-27
should be set to 1), the gain switched to the one multiplies
the switching rate.
Setting Value: 0x04
DI Name
CCLR Clear the pulse counter and the setting of parameter P2-50.
0: clear the position pulse deviation (It is suitable in PT
mode). When DI is ON, the accumulative pulse deviation of
the drive will be cleared to 0.
Setting Value: 0x05
DI Name
ZCLAMP When the speed is slower than the setting of zero speed
(P1-38), if the DI is ON, the motor stops ruuning.
Speed
Command
Setting value of
P1-38 (Zero speed)
ZCLAMP
input signal
Motor Speed
Setting value of
P1-38 (Zero speed)
Revision December, 2014
Function Description of Digital Input (DI)
Function Description of Digital Input (DI)
Function Description of Digital Input (DI)
Function Description of Digital Input (DI)
Function Description of Digital Input (DI)
OFF
Chapter 8 ParametersASDA-A2R Series
ON
Time
Trigger
Control
Method
Mode
Level
ALL
triggered
Trigger
Control
Method
Mode
Rising
ALL
edge
triggered
Trigger
Control
Method
Mode
Level
PT, PR,
triggered
S
Trigger
Control
Method
Mode
Rising
PT, PR
edge
triggered
, Level
triggered
Trigger
Control
Method
Mode
Level
S
triggered
8-279