Configure Inline-Power Disconnect-Precedence - Extreme Networks ExtremeWare Command Reference Manual

Version 7.5
Hide thumbs Also See for ExtremeWare:
Table of Contents

Advertisement

Power Over Ethernet Commands—Summit 300 and 400-24p Switches and Alpine PoE Module

configure inline-power disconnect-precedence

configure inline-power disconnect-precedence [lowest-priority | deny-port]
Description
Controls the disconnect function of power management.
NOTE
This command is available only on the Summit 300-48 switch.
Syntax Description
lowest-priority
Specifies that the port with the lowest priority is to be shut down when the next port connects.
deny-port
Specifies that the next port is denied power, regardless of priority.
Default
Deny-port
Usage Guidelines
The PoE controller disconnects one of the ports to prevent an overload on the power supply. The
disconnect function occurs when the power drain exceeds the available power budget because of a rise
in power consumption after power is allocated to the ports.
Example
The following example configures the disconnect precedence to disconnect the lowest priority port
when the next port attempts to connect:
configure inline-power disconnect-precedence lowest-priority
History
This command was first available in ExtremeWare 7.3e.
Platform Availability
This command is available only on the Summit 300-48 switch.