Ctrl Command load_program_file
• load_program_file automatically executes stop_execution, if:
Comments
(cont'd)
– the
– the
• The files RTC6OUT.out, RTC6ETH.out,
RTC6 software package. For easy identifying and archiving of different software
versions, the files are also delivered zipped (the zip file names RTC6<...>_<Version>.zip
include the version numbers). Copy or unzip the three files (of desired version) to the
hard drive of your PC.
• Assorted versions of the
and
software includes a text file with version information). load_program_file performs a
version compatibility check. If there is a version error, then the loaded programs remain
in RTC6 memory, but the board is released by
check and therefore is not available for further commands other than those not
requiring access rights
RTC6_VERSION_MISMATCH). To then load a correct program version, load_program_file
can be called. Hereby, temporary access rights are requested and released after the
download (if the board has not been acquired by another user program;
load_program_file does not perform an acquire_rtc).
RTC4RTC6
• The command parameter specifies a directory name with RTC6 (in contrast a file name
with the RTC4).
• load_program_file loads three files, with fixed formats and names (RTC6OUT.out,
RTC6RBF.rbf, RTC6DAT.dat) (see above).
• After execution of the command, the laser control is deactivated.
RTC5RTC6
Changed functionality.
• Notes on migrating the source code of RTC5 user programs, etc.: load_program_file
is downward compatible with the RTC5 and can continue to be used without
modification. Though you do not need to change your user program, keep in mind the
following:
– There is no checking of the
be outputted).
– Data transfer by the
– A running list is terminated without warning, similarly to the control command
stop_execution. Observe notes there about mirror positions etc.
– Other used error codes are provided as listed in the table above.
Version info
Available as of DLL 600, OUT 600, RBF 600.
References
RTC6 boards
Doc. Rev. 1.0.21 en-US
10 RTC6 Commands
BUSY list execution status
INTERNAL-BUSY list execution status
RTC6 DLL
RTC6DAT.dat
cannot be arbitrarily combined with another (each zip file in the RTC6
(get_last_error
BUSY list execution status
McBSP interface
is set
is set
RTC6RBF.rbf
RTC6DAT.dat
and
and the files RTC6OUT.out, RTC6ETH.out,
release_rtc
RTC6_ACCESS_DENIED
return code
(hence error code 13 is never
is deactivated without warning.
are included in the
RTC6RBF.rbf
directly after the version
|
511

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RTC6 PCIe Board and is the answer not in the manual?

Questions and answers

Related Products for Scanlab RTC6 PCIe Board

This manual is also suitable for:

Rtc6 ethernet board

Table of Contents

Save PDF