Lamp Current (Laser Power) - Scanlab RTC6 PCIe Board Installation And Operation Manual

Real time control of scan systems and lasers rtc6 software package v1.16.0
Table of Contents

Advertisement

Lamp Current (Laser Power)

To control the lamp current of a YAG laser, the 12-bit
analog output ports,
ANALOG OUT1
or
ANALOG OUT2
can be used. They are available at the
LASER
Connector, see
Figure
17.
ANALOG OUT2
is
also available at the MARKING ON THE FLY
socket connector, see
Figure
25.
To define the analog output signal, the control
command
write_da_x
and the delayed short
write_da_x_list
list command
are provided.
Alternatively, the lamp current can be controlled
digitally via the 8-bit digital output port (at the
EXTENSION 2 socket connector, see
Figure
24), see
also
Section "8-Bit Digital Output Port", page
81.
The commands for setting the 8-bit output port are
write_8bit_port,
write_8bit_port_list
or
write_port_list.
When the lamp current is changed, list execution can
be halted by
long_delay
until a constant laser power
has been achieved.
191
RTC6 boards
Doc. Rev. 1.0.21 en-US
7 Basic Functions for Scan Head Control and Laser Control