Ctrl Command set_jump_mode
• For usage of set_jump_mode, see
Comments
• A check (see also
if Flag = –1 (the initialization state) prior to the set_jump_mode call and/or if the
supplied tuning numbers do not match those stored on the board. Otherwise, only the
flag is switched.
For the check, the board must not be
INTERNAL-BUSY list execution
the data type to-be-returned by the scan system changes and "Automatic Laser
Control" is deactivated (both get restored at the end of the command).
Depending on results of the check, different error codes are returned (see above).
In case of error, Flag gets set to –1
If the check is successful, then you can afterward (even by
during processing of a list) switch freely between the states Flag = 1
(Jump Mode
(Jump Mode
performed.
• Use –1 as the tuning number if certain tunings should not be checked
(for example, because no intelliSCAN scan system is attached or specific tunings are
not
available –
if, after switching to
As a result, such tunings are neither checked nor switched on.
If the
the second scan head connector (B) is automatically set to –1 (even if others were
supplied).
If all tuning numbers are –1, then Flag is set to –1 (return value –1).
• Even after successful activation of
only occurs after the first subsequent 2D jump (see
page
Vector tuning
somewhat longer (approx. 250 ms), depending on the currently set tuning. You can
determine ahead of time whether this is so by calling set_jump_mode using the
currently set tuning as a parameter. If true (return value > 1, error code = 2), then you
can achieve the desired operational sequence by calling
first 2D jump to set the tuning to one that has been supplied by set_jump_mode.
RTC4RTC6
New command.
RTC5RTC6
Unchanged functionality.
Version info
Available as of DLL 600, OUT 600, RBF 600.
References
set_jump_mode_list, load_jump_table_offset,
RTC6 boards
Doc. Rev. 1.0.21 en-US
10 RTC6 Commands
Section "Requirements and Activation", page
status, because meanwhile
activated, vector mode deactivated) and Flag = 0
deactivated, vector mode activated) without another check having to be
Vector
tuning, for example, is not needed in pure drilling applications) or
Jump
tuning, it is not desirable to return to
Option "Second Scan Head Control"
217). If the currently set tuning then does not match the
specified by set_jump_mode, then the first switching can take
Chapter 8.1.5 "Jump Mode", page
BUSY list execution status
(Jump Mode
deactivated and disabled).
set_jump_mode_list
is not enabled, then the tuning numbers for
Jump Mode
(Flag = 1), the first servo switching
Section "Functional Principle",
control_command
set_jump_table
217.
218) is only performed
or
Vector
tuning.
Jump tuning
or
before the
664
Need help?
Do you have a question about the RTC6 PCIe Board and is the answer not in the manual?
Questions and answers