• If forward transformation included a clipping to
the edges of the positionable
the edges of the maximum possible range of
control values, then backward transformation
(ideally) calculates the Cartesian coordinates of
these edge values instead of the original values.
• By get_values, 4 arbitrary signals can be queried
at the same time. Example:
– the actual position of galvanometer scanner 2
by
StatusAX
– actual position of galvanometer scanner 1
by
StatusAY
– the actual z axis position
by
StatusBX
– an additional desired signal,
for example, LaserOn
get_value
In contrast,
useful for monitoring xy positioning because it is
only meant for querying a single signal and
multiple calls unavoidably lead to xyz values
across different points of time.
• By set_trigger, you can simultaneously record
2 arbitrary signals by 2 measurement channels
(set_trigger4
4 signals by 4 measurement
channels;
set_trigger8
measurement channels).
• The assignment of the values read out by
get_values
or
set_trigger
backward transformation can be specified with
parameter Code at:
transform
get_transform/get_transform_offset
• In addition, it is possible to specify which partial
transformations are to be performed with:
transform
get_transform/get_transform_offset
• Values queried by get_values, or arbitrary
synthetic values can be backward transformed by
transform. During backward transformation of
synthetic values beyond the forward
transformation's achievable
sometimes are only calculated by extrapolation,
due to possible range exceedances or other
errors.
RTC6 boards
Doc. Rev. 1.0.21 en-US
8 Advanced Functions for Scan Head Control and Laser Control
Image Field
or to
(not: get_values) is not
8 signals by 8
to x, y or z for the
Image
Field, values
• If the user program binarily stores both the
recorded values and the transferred
transformation data (see get_waveform), then
subsequent backward transformation by
transform
(not
get_transform/get_transform_offset) can also
be executed offline, hence without needing to
further access a RTC6 PCIe Board.
• If
control_command
is used to specify
positioning error rather than actual position as
the to-be-returned data type by the scan system,
then it is not possible to directly compare the
originally defined pattern with the marked
pattern. But you can check if the scan system
correctly processed the RTC6 PCIe Board output
values. This is particularly useful if backward
transformation of actual values is not (fully)
possible or when it cannot be determined if
deviations between backward-transformed
actual positions and originally defined coordinate
values are due to scan system error or clipping
during forward transformation.
215

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RTC6 PCIe Board and is the answer not in the manual?

Subscribe to Our Youtube Channel

Related Products for Scanlab RTC6 PCIe Board

This manual is also suitable for:

Rtc6 ethernet board

Table of Contents

Save PDF