SetPositionScale
• On
– If the scaling factor for scaling the position
values is changed, then the user program
calibration factor for calculating RTC6 control
values (in bits) from the desired
position values (in mm), see
"Image Field Size and Image Field Calibration",
page
167, needs to be subjected to an inverse
proportional scaling. In addition, the
jump speed and mark speed should be
adjusted.
– The currently set scaling factor can be queried
with Data =
053F
.
H
• On
SetPosAcknowledgeLevel
– The limit value must be specified related to a
16-bit position range.
– The default start behavior is for the scan system
to set the limit value to 0.28% of the full
angular range of an axis (LSB16 or 1/65536,
Code
= 183 = B7
LOW
or reset.
If other limit values are desired, they must be
separately set for each axis
SCANLAB recommends setting only limit values
(Code
) > 14
(that is, 0.03% of the full
LOW
H
position range). Lower values can lead to
frequent system safety shutdowns due to
Position Acknowledge time outs (set position
not reached for an excessive time).
• On
Store/RestoreTransmissionMode
– control_command( Data =
if a power-up or reset was executed after the
most recent execution of control_command( Data
=
17FF
).
H
RTC6 boards
Doc. Rev. 1.0.21 en-US
20 Appendix E: iDRIVE Scan Systems – Control Commands and Signals Transmitted to RTC Boards
Image Field
Chapter 7.3.2
) after every power-up
H
(Code
=
15
).
HIGH
H
1700
) has no effect
H
983