Scanlab RTC6 PCIe Board Installation And Operation Manual page 504

Real time control of scan systems and lasers rtc6 software package v1.16.0
Table of Contents

Advertisement

Ctrl Command load_jump_table_offset
Result
10
(cont'd)
11
13
Comments
• For information on command usage, see
Jump Delays", page
• See also
• Format requirements for placing the table with
file are described in
page
appropriate values for the complete jump length range.
• load_jump_table_offset overwrites any previously loaded
Jump
• If Name = filename, then the table number No is loaded. The other parameters are not
used.
• If Name = NULL, then the
loaded (if
set_jump_mode
and ListPos are used (see
page
Jump Mode
enabled by
• load_jump_table_offset is not executed
– the
– the
• load_jump_table_offset is even executed, if:
– a list has been paused by
• During the runtime of load_jump_table_offset,
• Before loading a table, load_jump_table_offset performs a
produces error code 4 in case of error.
• The table can be saved by create_dat_file.
RTC4RTC6
New command.
There is no
RTC5RTC6
Unchanged functionality.
Version info
Available as of DLL 600, OUT 600, RBF 600.
Reference
load_jump_table, set_jump_mode, set_jump_mode_list, get_jump_table,
set_jump_table,
RTC6 boards
Doc. Rev. 1.0.21 en-US
10 RTC6 Commands
Only if Name = NULL: Param error: HeadNo or ListPos invalid.
PCI error during download
The specified table number could not be found in the file.
218.
Chapter 8.1.5 "Jump Mode", page
Section "Notes on Loading Determined Jump Delay Values",
219. When loading the table, the RTC6 uses linear interpolation to establish
Mode.
Jump Delay
Jump Mode
has been previously enabled and activated successfully by
(Flag = 1)). Here, the parameters PosAck, Offset, MinDelay, MaxDelay
Section "Automatic Determination of the Jump Delay Table",
221).
takes effect upon the next 2D jump only if it has been activated and
set_jump_mode
or activated by set_jump_mode_list.
BUSY list execution status
INTERNAL-BUSY list execution status
set_wait (PAUSED list execution status
RTC4 Compatibility Mode
create_dat_file
return code RTC6_SEND_ERROR).
(get_last_error
Section "Jump-Length-Dependent
217.
Jump Delay
table for head No is automatically determined and
return code RTC6_BUSY), if:
(get_last_error
is set
is set
External
Starts are suppressed.
for this command.
data points into the text
Jump Delay
tables for
set)
DSP
memory check that
504

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RTC6 PCIe Board and is the answer not in the manual?

Questions and answers

Related Products for Scanlab RTC6 PCIe Board

This manual is also suitable for:

Rtc6 ethernet board

Table of Contents

Save PDF