Get_Master_Slave - Scanlab RTC6 PCIe Board Installation And Operation Manual

Real time control of scan systems and lasers rtc6 software package v1.16.0
Table of Contents

Advertisement

Ctrl Command get_master_slave
Function
Returns the master/slave status of the addressed RTC6 board.
MasterSlaveStatus = get_master_slave()
Call
Result
Master/slave status.
As an unsigned 32-bit value.
Information whether a further RTC6 board is connected to the Master or Slave connector
of the addressed RTC6 board:
Bit #0
(LSB)
Bit #1
Bit #2
...
Bit #31
Information, whether the addressed board is operated as a master, slave or single board:
= 0
= 1
= 2
= 3
Comments
• See
• get_master_slave only returns the status, if the addressed RTC6 board has been
previously initialized by load_program_file. Otherwise, 0 is returned.
RTC4RTC6
New command.
RTC5RTC6
Unchanged functionality.
Version info
Available as of DLL 600, OUT 600, RBF 600.
References
sync_slaves
RTC6 boards
Doc. Rev. 1.0.21 en-US
10 RTC6 Commands
= 1:
A RTC6 board is connected to the Slave connector.
= 1:
A RTC6 board is connected to the Master connector.
= 0.
...
= 0.
Single board.
Slave without any further downstream slave board.
Master.
Slave together with a downstream slave board.
Chapter 6.6.3 "Master/Slave Operation", page
124.
417

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RTC6 PCIe Board and is the answer not in the manual?

Subscribe to Our Youtube Channel

Related Products for Scanlab RTC6 PCIe Board

This manual is also suitable for:

Rtc6 ethernet board

Table of Contents

Save PDF