Number_Of_Correction_Tables - Scanlab RTC6 PCIe Board Installation And Operation Manual

Real time control of scan systems and lasers rtc6 software package v1.16.0
Table of Contents

Advertisement

Ctrl Command number_of_correction_tables
Function
Defines the maximum number of allowed correction tables.
number_of_correction_tables( Number )
Call
Number
Parameters
Comments
• For outside the allowed value range, number_of_correction_tables is ignored
(get_last_error
• number_of_correction_tables serves to protect other commands (for example, such
as
load_correction_file
• Existing user programs do not have to be changed. The exception is, if user input is to
be rejected (using explicit RTC6 error messages) in the future.
• number_of_correction_tables refers only to subsequent command executions.
Existing assignments of correction tables cannot be corrected automatically. This is
particularly important, if RTC6 boards that have been initialized by other
user programs are subsequently acquired.
RTC4RTC6
New command.
RTC5RTC6
Changed impacts (the RTC5-command has not been documented due to the restricted user
group).
Version info
Available as of DLL 609, OUT 609, RBF 613.
References
load_correction_file, select_cor_table,
RTC6 boards
Doc. Rev. 1.0.21 en-US
10 RTC6 Commands
Maximum number of allowed correction tables.
As an unsigned 32-bit value.
Allowed value range: [1...8].
Default after load_program_file: 8. See also
Correction Tables", page
241.
return code RTC6_PARAM_ERROR).
and select_cor_table) from unwanted table numbers.
Chapter 8.5.3 "Using Several
select_cor_table_list
551