"Spot Distance Control"
The
"Spot Distance Control"
available for scan systems equipped with
SCANahead servo control (for example, excelliSCAN
series).
With set_auto_laser_control(
("Spot Distance
Control"), temporal output pulses
are controlled to a geometrically constant pulse
distance. This pulse distance is defined by
spot_distance
or spot_distance_ctrl. The
parameters Value,
MinValue
meaning with the
"Spot Distance Control"
functionality.
The speed correction occurs with
Mode
= 2 + 16 + (optionally) 32, (see above).
"Spot Distance Control"
cannot be combined with
Mode
= 1, 2 or 5.
The correction is more precise and dynamic than the
Ctrl
comparable control with
successful use, a laser with "pulse-on-demand"
functionality should be used that outputs laser pulses
immediately when triggered by the LASER1 signal.
Frequency modulations are set with an accuracy of
1/64 µs for the pulse distance.
A comparison of a typical marking result with
"Automatic Laser Control"
"Automatic Laser Control" is shown in
As an alternative to
set_auto_laser_control
Ctrl
= 7, the marking shown in
be carried out with
Sky Writing
However, when using
set_auto_laser_control
Ctrl
= 7 the process time is often shorter.
RTC6 boards
Doc. Rev. 1.0.21 en-US
7 Basic Functions for Scan Head Control and Laser Control
functionality is only
Ctrl
= 7 )
MaxValue
and
have no
= 5 (HalfPeriod). For
(Ctrl
= 7) and without
Figure
57.
with
Figure 58
could also
switched on.
with
Notes
• set_auto_laser_control(
("Spot Distance
Control") cannot be combined
with:
– "Vector-controlled laser control" by
set_vector_control (Ctrl
(1)
–
Laser Mode 4
(1)
–
Laser Mode 6
•
set_trigger/set_trigger4/set_trigger8
(signal 24) records an internal control signal but
not HalfPeriod.
(1) In
Laser Mode 4
and
Laser Mode
signal is outputted that cannot be varied.
Ctrl
= 7 )
= 5) (HalfPeriod)
6, only a standby
202