Periodical I/O Signals - Scanlab RTC6 PCIe Board Installation And Operation Manual

Real time control of scan systems and lasers rtc6 software package v1.16.0
Table of Contents

Advertisement

9.4 Periodical I/O Signals

By
periodic_toggle
and periodic_toggle_list,
periodically repeated signals can be outputted at a
selectable IO port:
ANALOG OUT1
output port, see
Analog Output Port 1 and 2", page 74
ANALOG OUT2
output port, see
Analog Output Port 1 and 2", page 74
• 8-bit digital output port, see
Digital Output Port", page 81
• 16-bit digital output port, see
Digital Input Port and 16-Bit Digital Output Port",
page 78
• 2-bit digital output port, see
Digital Output Port", page 74
Thereby, for example, external peripheral equipment
can be triggered synchronously to list execution.
RTC6 boards
Doc. Rev. 1.0.21 en-US
9 Programming Peripheral Interfaces
Notes
• At a set_end_of_list,
Section "12-Bit
Section "12-Bit
Section "8-Bit
Section "16-Bit
Section "2-Bit
stop_execution
/STOP the periodical signals continue, even if they
have been activated by the list command
periodic_toggle_list.
periodic_toggle
and
periodic_toggle_list
toggle endless with Count = 2
or external
32
–1.
301