Scanlab RTC6 PCIe Board Installation And Operation Manual page 669

Real time control of scan systems and lasers rtc6 software package v1.16.0
Table of Contents

Advertisement

Ctrl Command set_laser_control
Parameters
Bit #7
(cont'd)
Bit #8
...
Bit #15
Bit #16
Bit #17
Bit #18
Bit #19
Bit #20
Bit #21
Bit #22
Bit #23
Bit #24
Bit #25
Bit #26
Bit #27
Bit #28
Bit #29
Bit #30
Bit #31
Comments
• In the default setting (after load_program_file), all bits are set to 0. After a hardware
reset, however, the settings become effective following the first-time call of
set_laser_control. Prior to this, all laser control signal outputs (LASERON, LASER1 and
LASER2) are in the high-impedance mode. TTL states (LOW or HIGH) only become
available when set_laser_control is called to define the desired TTL level, see also
Chapter 7.4 "Laser Control", page
deactivates the
activation.
RTC6 boards
Doc. Rev. 1.0.21 en-US
10 RTC6 Commands
= 0:
The "constant pulse length" mode is switched off
(default setting).
= 1:
The "constant pulse length" mode is switched on.
See
Chapter 7.4.8 "Pulse Picking Laser Mode", page 196
and set_pulse_picking_length.
Reserved.
Reserved.
For the automatic suppression of
PowerOK of the head A, x axis.
Like
Bit
#16, but: TempOK of the head A, x axis.
Like
Bit
#16, but: PosAck of the head A, x axis.
Like
Bit
#16, but: PowerOK of the head A, y axis.
Like
Bit
#16, but: TempOK of the head A, y axis.
Like
Bit
#16, but: PosAck of the head A, y axis.
Like
Bit
#16, but: PowerOK of the head B, x axis.
Like
Bit
#16, but: TempOK of the head B, x axis.
Like
Bit
#16, but: PosAck of the head B, x axis.
Like
Bit
#16, but: PowerOK of the head B, y axis.
Like
Bit
#16, but: TempOK of the head B, y axis.
Like
Bit
#16, but: PosAck of the head B, y axis.
= 1:
In case of error, automatic monitoring (automatic suppression of
Laser Control
Signals) automatically generates a /STOP signal
(list stops,
Laser Control Signals
= 1:
In case of error according to
forwarded as /Master-STOP (see
all Master/Slave-connected RTC6 boards. See master_slave_config.
Reserved.
Reserved.
Signals, set_laser_control must be called for first-time
Laser Control
Laser Control Signals
get permanently switched off).
Bit
#28, the
stop_execution
Figure
68) to
184. Even after load_program_file, which
is used:
is
669