Ctrl Command set_auto_laser_params
Function
Specifies the to-be-controlled signal parameter of the "Automatic Laser Control", the 100%
value and its corresponding limit values.
set_auto_laser_params( Ctrl, Value, MinValue, MaxValue )
Call
Ctrl
Parameters
Value
MinValue
MaxValue
Comments
• For information on using set_auto_laser_params, see
Laser Control"", page
• The meaning of the parameters is identical to that of
comments there). However, set_auto_laser_params can neither start nor terminate
"Automatic Laser Control".
• If the value for Ctrl is invalid (0 or > 7), then set_auto_laser_params is not executed
(get_last_error
RTC4RTC6
New command.
RTC4 Compatibility
RTC5RTC6
Unchanged functionality.
Version info
Available as of DLL 600, OUT 600, RBF 600.
Last change DLL 609, OUT 609, RBF 613: Ctrl = 7.
References
set_auto_laser_control,
Delayed Short

set_auto_laser_params_list

List Command
Function
Like set_auto_laser_params, but a delayed short list command.
set_auto_laser_params_list( Ctrl, Value, MinValue, MaxValue )
Call
Ctrl
Parameters
Value
MinValue
MaxValue
• If the value for Ctrl is invalid (0 or > 7), then set_auto_laser_params_list is replaced
Comments
with a
RTC4RTC6
New command.
RTC4 Compatibility
RTC5RTC6
Unchanged functionality.
Version info
Available as of DLL 600, OUT 600, RBF 600.
Last change DLL 609, OUT 609, RBF 613: Ctrl = 7.
References

set_auto_laser_params,

RTC6 boards
Doc. Rev. 1.0.21 en-US
10 RTC6 Commands
The to-be-controlled signal parameter (see set_auto_laser_control).
Allowed value range: [1...7].
100% value. See set_auto_laser_control.
Lower range limit. See set_auto_laser_control.
Upper range limit. See set_auto_laser_control.
197.
return code RTC6_PARAM_ERROR).
Mode: see set_auto_laser_control.
set_auto_laser_params_list
Like set_auto_laser_params.
Like set_auto_laser_params.
Like set_auto_laser_params.
Like set_auto_laser_params.
return code RTC6_PARAM_ERROR).
list_nop (get_last_error
Mode: see set_auto_laser_control.
set_auto_laser_control
Chapter 7.4.9 ""Automatic
set_auto_laser_control
(see also
617

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RTC6 PCIe Board and is the answer not in the manual?

Subscribe to Our Youtube Channel

Related Products for Scanlab RTC6 PCIe Board

This manual is also suitable for:

Rtc6 ethernet board

Table of Contents

Save PDF