Scanlab RTC6 PCIe Board Installation And Operation Manual page 472

Real time control of scan systems and lasers rtc6 software package v1.16.0
Table of Contents

Advertisement

Variable
laser_on_pulses_list
List Command
Comments
• If Pulses = 0, then laser_on_pulses_list has no effect (the LASERON signal is not
(cont'd)
switched on). Then laser_on_pulses_list becomes a short list command.
• The LASERON signal must first be defined and enabled by
enable_laser
"Laser Control", page
• While tlaser_on_pulses_list is executed, the set position of the scanners is not
changed. The next list command is executed when the programmed time interval
Period has passed.
• The
ignored.
• Any softstarts that were defined are not executed.
RTC4RTC6
New command.
RTC5RTC6
Unchanged functionality.
Version info
Available as of DLL 600, OUT 600, RBF 600.
References
laser_on_list,
RTC6 boards
Doc. Rev. 1.0.21 en-US
10 RTC6 Commands
before it can be switched on with laser_on_pulses_list, see
184.
Wobbel
Mode, see
Chapter 8.4 "Wobbel Mode", page
para_laser_on_pulses_list
set_laser_control
or
Chapter 7.4
232, is retained but
472

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RTC6 PCIe Board and is the answer not in the manual?

Related Products for Scanlab RTC6 PCIe Board

This manual is also suitable for:

Rtc6 ethernet board

Table of Contents

Save PDF