Get_Standby - Scanlab RTC6 PCIe Board Installation And Operation Manual

Real time control of scan systems and lasers rtc6 software package v1.16.0
Table of Contents

Advertisement

Ctrl Command get_standby
Function
Returns the currently set standby parameters.
get_standby( &HalfPeriod, &PulseLength )
Call
HalfPeriod
Returned
parameter
values
PulseLength
Comments
• For usage of get_standby, see
page
RTC4RTC6
New command.
In
RTC4 Compatibility
by 8.
RTC5RTC6
Unchanged functionality.
Version info
Available as of DLL 600, OUT 600, RBF 600.
References
set_standby
RTC6 boards
Doc. Rev. 1.0.21 en-US
10 RTC6 Commands
Half of the currently set standby output period of the standby pulses.
As a pointer to an unsigned 32-bit value.
1 bit equals 1/64 µs.
Currently set pulse length of the standby pulses.
As a pointer to an unsigned 32-bit value.
1 bit equals 1/64 µs.
186.
Mode, the RTC6 divides the values for HalfPeriod and PulseLength
Section "Signals for "Laser Standby" Operation",
425