mark_serial_abs

Command
Function
Marks the current serial number of the serial-number-set most recently selected by
select_serial_set_list
format at the current position. In the called indexed text strings or characters (see below),
any absolute
current coordinates at the time of the call). Afterward the serial number is (optionally)
automatically incremented.
mark_serial_abs( Mode, Digits )
Call
Mode
Parameters
Digits
Comments
• mark_serial_abs has the same effect as mark_serial; however, internal calling of the
indexed text strings (or characters) is by
• If the command lists of the called indexed text strings (or characters) contain no
absolute commands, then there is no difference between mark_serial_abs and
mark_serial.
RTC4RTC6
New command.
RTC5RTC6
Unchanged functionality.
Version info
Available as of DLL 600, OUT 600, RBF 600.
mark_serial
References
RTC6 boards
Doc. Rev. 1.0.21 en-US
10 RTC6 Commands
(or of serial-number-set 0 after load_program_file) in the selected
Vector
Commands and
"Arc"
See mark_serial.
See mark_serial.
Commands receive an offset (based on the
list_call_abs
instead of list_call.
537