Ctrl Command set_angle
Function
Uses a specified rotation angle to define the rotation matrix M
coordinate transformations, see
set_angle( HeadNo, Angle, at_once )
Call
HeadNo
Parameters
Angle
at_once
Comments
• See also
• As of DLL 617, OUT 617 the following applies for HeadNo = 4: The global coordinate
transformations are generally available, even outside a
RTC4RTC6
New command.
RTC5RTC6
Unchanged functionality.
Last change DLL 617, OUT 617: HeadNo = 4.
Version info
References
set_angle_list, set_matrix, set_offset,
RTC6 boards
Doc. Rev. 1.0.21 en-US
10 RTC6 Commands
Chapter 8.2 "Coordinate Transformations", page
Number of the scan head connector. As an unsigned 32-bit value.
= 1:
The definition only affects the first scan head connector.
= 2:
The definition only affects the second scan head connector.
= 0, 3: The definition affects both scan head connectors.
= 4:
The definition affects the virtual
Only the 3 least significant bits are evaluated.
Rotation angle. In degrees.
As a 64-bit IEEE floating point value.
Positive angles result in a counterclockwise rotation around the centerpoint of
the
Image
Field.
Determines when the defined transformation becomes effective.
As an unsigned 32-bit value.
Like set_matrix.
Chapter 8.2 "Coordinate Transformations", page
for all subsequent
R
Image Field
(see also comments).
224.
Processing-on-the-fly
set_scale
224.
Session.