Scanlab RTC6 PCIe Board Installation And Operation Manual page 189

Real time control of scan systems and lasers rtc6 software package v1.16.0
Table of Contents

Advertisement

Notes
• LASER1 signals and LASER2 signals are
– activated by: HalfPeriod
PulseLength
0
– deactivated by: HalfPeriod = 0 and/or
PulseLength = 0 (default setting after
load_program_file)
• The LASER2 signal is phase-shifted by half a signal
period in relation to the LASER1 signal. It can be
used for the control of a second laser tube. By
set_laser_control (Bit #1
be exchanged with each other. To control laser
power, the pulse length of the LASER1 and
LASER2 signals can be varied. Both signals share
the same pulse lengths and periods.
• For the LASER1 signals and LASER2 signals, half
of the output period must be specified.
set_laser_pulses
and
set_laser_timing
delayed short list commands. They can also be
used to change the laser parameters between
two
Mark
Commands.
The time base for the signals is always:
– 1/64 µs in
RTC6 Standard
see also
Section "RTC6 Standard Mode",
page 168
– 1/8 µs in
RTC4 Compatibility
see also
Section "RTC4 Compatibility Mode",
page 168
Pulse Completion, page 186
LASER2 signals.
RTC6 boards
Doc. Rev. 1.0.21 en-US
7 Basic Functions for Scan Head Control and Laser Control
0 and
= 1), both signals can
are
Mode,
Mode,
affects also
189