11D-120 1K LCSS to Machine Communications Interface
RAP
All communications between the machine and 1K LCSS are conducted through a single inter-
face cable.
Procedure
Check the 1K LCSS PWB DIP switch settings, refer to 11E-120 1K LCSS PWB DIP Switch
Settings RAP.
Go to 03-360, 03-408 to 03-410, 03-418 IOT to Output Device Error Rap.
Status Indicator RAPs
11D-120, 11E-120
11E-120 1K LCSS PWB DIP Switch Settings RAP
To show the correct settings for the DIP switches on the 1K LCSS PWB.
Procedure
Problems that can result from incorrect DIP switch settings are:
•
False jam clearance instructions for the 1K LCSS and/or the machine exit area.
•
Communication errors between the 1K LCSS and machine.
•
Erratic behavior of the 1K LCSS.
Check the DIP switch settings, Figure 1. If necessary, switch off the machine, GP 14. Correct
the DIP switch setting, then switch on the machine, GP 14.
Figure 1 DIP switch settings
August 2007
2-370