11A-120 Bin 1 Overload RAP

Use this RAP to resolve a fault on the bin 1 90% full sensor.
Procedure
NOTE: In diagnostics, actuating any 1K LCSS sensor or switch can change the displayed state
on the UI. Make sure that the correct sensor or switch is tested.
Enter dC330, code 11-331, bin 1 90% full sensor, Q11-331. Actuate Q11-331. The
changes.
Y
N
Go to Flag 1. Check Q11-331.
Refer to:
11F-120 1K LCSS PWB Damage RAP.
GP 11, How to Check a sensor.
Figure 1.
P/J2, 1K LCSS PWB
11C-120 1K LCSS Power Generation RAP.
Repair or install new components as necessary:
Bin 1 90% full sensor, PL 11.106 Item 5.
1K LCSS PWB, PL 11.124 Item 1.
Perform SCP 6 Final Actions.
Bin 1 90% full sensor Q11-331
Figure 1 Component location
WorkCentre 5687 Family
display
August 2007
2-365
Figure 2 Circuit diagram