Avaya S8700 Maintenance Manual page 2269

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

SYSTEM (System)
Table 8-601. SYSTEM Error 605 AUX Data, Failure of Planned Interchange
Aux
Data
1352
1353
1355
1356
1357
1358
1359
1360
1361
1369
1370
1371
1372
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1406
1418
2500
555-233-143
See Note
Explanation
1
Standby SOH "non-functional"
1
Standby SOH not "functional"
1
Handshake Communication with standby server is down
1
Memory Shadowing not enabled
1
Standby memory not refreshed
2
Mass Storage System was in use
3
PKT-INT link migration failed
1
Interchange failed *
4
SW-CTL failure
7
Could not suspend G3-MT connectivity *
4
Could not freeze active SW-CTL *
5
Internal Error associated with processor interrupts *
6
Minor alarm on standby SYSAM or PKT-INT
Server
Duplication not administered
3
PKT-INT Link Migration failure in Begin Step *
3
PKT-INT Link Migration denied, (peer test in progress)
3
PKT-INT Link Migration failure in Completion Step *
3
PKT-INT Link Migration failure in Finish Step *
4
Could Not Idle SW-CTL dual port RAM *
4
Could Not Refresh SW-CTL dual port RAM *
5
Internal Error (could not get duplication status)
5
Unable to inhibit standby Maintenance Monitor
5
Failure to determine standby server's alarm status
server
3
Active
8
Active Duplication Interface circuit pack is in a bad state and
needs to be reset.
5
Internal Software failure (* sometimes)
's PKT-INT in held-reset state
Issue 1 May 2002