Parameters

Overview of parameters

1.1
Overview of parameters
1.1.1

Explanation of list of parameters

Basic structure of parameter descriptions
The data in the following example has been chosen at random. The table below
shows all the information which can be included in the description of a parameter.
Some of the information is optional.
The structure of the parameter list (see Section 1.2) is as follows:
- - - - - - - - - - - - - - - - - - - - Start of example- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
pxxxx[0...n]
BICO: Full parameter name / Abbreviated name
Drive object (function
Changeable in: C1, C2, U, T
module)
Data type: Integer16
P group: Cl.-lp. control
Min
0.00 [Nm]
Description:
Text
Values:
0:
1:
2:
etc.
Recommenda-
Text
tion:
Index:
[0] = Name and meaning of index 0
[1] = Name and meaning of index 1
[2] = Name and meaning of index 2
etc.
Bit array:
Bit
Signal name
00
Name and meaning of bit 0
01
Name and meaning of bit 1
02
Name and meaning of bit 2
etc.
Depends on:
Text
see also: pxxxx, rxxxx
see also: Fxxxxx, Axxxxx
Danger!
Corresponds to safety notice "Danger with warning triangle".
Warning!
Corresponds to safety notice "Warning with warning triangle".
Caution!
Corresponds to safety notice "Caution with warning triangle".
Caution:
Corresponds to safety notice "Caution without warning triangle".
Notice:
Corresponds to safety notice "Notice without warning triangle".
Note:
Information which might be useful.
- - - - - - - - - - - - - - - - - - - - End of example- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
1-12
Name and meaning of value 0
Name and meaning of value 1
Name and meaning of value 2
Data set: CDS
Unit group: TIME
Max
10.00 [Nm]
0-signal
No
No
No
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Access level: 2
Function diagram: 2080
Unit selection: -
Factory Setting
2.00 [Nm]
1-signal
FP
Yes
8010
Yes
-
Yes
8012