p1038[0...n]
Motorized potentiometer, minimum speed / Mop n_min
VECTOR
Can be changed: U, T
Data type: Floating Point
P-Group: Setpoints
Min
-210000.000 [1/min]
Description:
Sets the minimum speed/velocity for the motorized potentiometer.
Note:
This parameter is automatically pre-assigned in the commissioning phase.
The setpoint output from the motorized potentiometer is limited to this value.
p1039[0...n]
BI: Motorized potentiometer, inversion / Mop inversion
VECTOR
Can be changed: T
Data type: Unsigned32
P-Group: Setpoints
Min
-
Description:
Sets the signal source to invert the maximum or minimum speed/velocity for the motorized potentiometer.
Dependency:
Refer to: p1037, p1038
Note:
The inversion is only active during "motorized potentiometer raise" or "motorized potentiometer lower".
p1040[0...n]
Motorized potentiometer, starting value / Mop start value
VECTOR
Can be changed: U, T
Data type: Floating Point
P-Group: Setpoints
Min
-210000.000 [1/min]
Description:
Sets the starting value for the motorized potentiometer. This starting value becomes effective after the drive has
been powered-up.
Dependency:
Only effective if p1030.0 = 0.
Refer to: p1030
p1041[0...n]
BI: Motorized potentiometer, manual/automatic / Mop manual/auto
VECTOR
Can be changed: T
Data type: Unsigned32
P-Group: Setpoints
Min
-
Description:
Sets the signal source to change over from manual to automatic when using a motorized potentiometer.
In the manual mode, the setpoint is changed using two signals - raise and lower. In the automatic mode, the set-
point must be interconnected via a connector input.
Dependency:
Refer to: p1030, p1035, p1036, p1042
Note:
The effectiveness of the internal ramp-function generator can be set in automatic mode.
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Data set: DDS
Units group: SPEED_ROT
Max
210000.000 [1/min]
Data set: CDS
Units group: -
Max
-
Data set: DDS
Units group: SPEED_ROT
Max
210000.000 [1/min]
Data set: CDS
Units group: -
Max
-
Parameters
Parameter list
Access level: 2
Function diagram: 3020
Unit selection: -
Factory setting
0.000 [1/min]
Access level: 3
Function diagram: 3020
Unit selection: -
Factory setting
0
Access level: 2
Function diagram: 3020
Unit selection: -
Factory setting
0.000 [1/min]
Access level: 3
Function diagram: 3020
Unit selection: -
Factory setting
0