p4030
BI: TB30 signal source for terminal DO 0 / TB30 S_Src DO 0
TB30
Can be changed: U, T
Data type: Unsigned32
P-Group: Commands
Min
-
Description:
Sets the signal source for terminal DO 0 (X481.5) of the terminal board 30 (TB30).
Note:
DO: Digital output
p4030
BI: TM31 signal source for terminal DO 0 / TM31 S_src DO 0
TM31
Can be changed: U, T
Data type: Unsigned32
P-Group: Commands
Min
-
Description:
Sets the signal source for the digital output DO 0 (X542.1, X542.2, X542.3) of terminal module 31 (TM31).
Digital output 0 of TM31 is a relay output.
If the signal at the binector input p4030 is low, then terminal COM 0 (X542.2) is connected to NC 0 (X542.1). This
connection also matches the mechanical quiescent setting of the relay.
If the signal at the binector input p4030 is high, then terminal COM 0 (X542.2) is connected to NO 0 (X542.3).
Note:
DO: Digital output
NC: Normally closed contact
NO: Normally open contact
p4031
BI: TB30 signal source for terminal DO 1 / TB30 S_Src DO 1
TB30
Can be changed: U, T
Data type: Unsigned32
P-Group: Commands
Min
-
Description:
Sets the signal source for terminal DO 1 (X481.6) of the terminal board 30 (TB30).
Note:
DO: Digital output
p4031
BI: TM31 signal source for terminal DO 1 / TM31 S_src DO 1
TM31
Can be changed: U, T
Data type: Unsigned32
P-Group: Commands
Min
-
Description:
Sets the signal source for the digital output DO 1 (X542.4, X542.5, X542.6) of terminal module 31 (TM31).
Digital output 1 of TM31 is a relay output.
If the signal at the binector input p4031 is low, then terminal COM 1 (X542.5) is connected to NC 1 (X542.4). This
connection also matches the mechanical quiescent setting of the relay.
If the signal at the binector input p4031 is high, then terminal COM 1 (X542.5) is connected to NO 1 (X542.6).
Note:
DO: Digital output
NC: Normally closed contact
NO: Normally open contact
1-288
Data set: -
Units group: -
Max
-
Data set: -
Units group: -
Max
-
Data set: -
Units group: -
Max
-
Data set: -
Units group: -
Max
-
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Access level: 1
Function diagram: 1790,
9102
Unit selection: -
Factory setting
0
Access level: 1
Function diagram: 1840,
9556
Unit selection: -
Factory setting
0
Access level: 1
Function diagram: 9102
Unit selection: -
Factory setting
0
Access level: 1
Function diagram: 1840,
9556
Unit selection: -
Factory setting
0