Siemens SINAMICS G List Manual page 239

Table of Contents

Advertisement

r2056[0...19]
PROFIBUS diagnostics expert / PB diag experts
CU
Can be changed: -
Data type: Unsigned16
P-Group: Communication
Min
-
r2060[0...14]
CO: PROFIBUS PZD receive double word / PB PZD recv DW
VECTOR
Can be changed: -
Data type: Integer32
P-Group: Communication
Min
-
Description:
Connector output to interconnect PZD (setpoints) with double word format received from the PROFIBUS master.
Index:
[0] = PZD 1 + 2
[1] = PZD 2 + 3
[2] = PZD 3 + 4
[3] = PZD 4 + 5
[4] = PZD 5 + 6
[5] = PZD 6 + 7
[6] = PZD 7 + 8
[7] = PZD 8 + 9
[8] = PZD 9 +10
[9] = PZD 10 + 11
[10] = PZD 11 + 12
[11] = PZD 12 + 13
[12] = PZD 13 + 14
[13] = PZD 14 + 15
[14] = PZD 15 + 16
Dependency:
Refer to: r2050
p2061[0...14]
CI: PROFIBUS PZD send double word / PB PZD send DW
VECTOR
Can be changed: U, T
Data type: Unsigned32
P-Group: Communication
Min
-
Description:
Selects the PZD (actual values) with double word format to be sent to the PROFIBUS master.
Index:
[0] = PZD 1 + 2
[1] = PZD 2 + 3
[2] = PZD 3 + 4
[3] = PZD 4 + 5
[4] = PZD 5 + 6
[5] = PZD 6 + 7
[6] = PZD 7 + 8
[7] = PZD 8 + 9
[8] = PZD 9 +10
[9] = PZD 10 + 11
[10] = PZD 11 + 12
[11] = PZD 12 + 13
[12] = PZD 13 + 14
[13] = PZD 14 + 15
[14] = PZD 15 + 16
Dependency:
Refer to: p2051
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Data set: -
Units group: -
Max
-
Data set: -
Units group: -
Max
-
Data set: -
Units group: -
Max
-
Parameters
Parameter list
Access level: 4
Function diagram: -
Unit selection: -
Factory setting
-
Access level: 3
Function diagram: 2440,
2460
Unit selection: -
Factory setting
-
Access level: 3
Function diagram: 2470
Unit selection: -
Factory setting
0
1-239