Siemens SINAMICS G List Manual page 86

Table of Contents

Advertisement

Parameters
Parameter list
p0421[0...n]
Absolute encoder rotary multi-turn resolution / Enc abs multiturn
VECTOR
Can be changed: C2
Data type: Unsigned16
P-Group: Encoder
Min
0
Description:
Sets the number of rotations that can be resolved for a rotary absolute encoder.
p0422[0...n]
Absolute value encoder linear measuring step resolution / Enc abs meas step
VECTOR
Can be changed: C2
Data type: Unsigned32
P-Group: Encoder
Min
0 [nm]
Description:
Sets the resolution of the absolute position for a linear absolute encoder.
Note:
The serial protocol of an absolute encoder provides the position with a certain resolution , e.g. 100 nm. This value
must be entered here.
p0423[0...n]
Absolute value encoder rotary single-turn resolution / Enc abs singleturn
VECTOR
Can be changed: C2
Data type: Unsigned32
P-Group: Encoder
Min
0
Description:
Sets the number of measuring steps per revolution for a rotary absolute value encoder. The resolution refers to the
absolute position.
p0424[0...n]
Encoder, linear zero mark distance / Enc lin dist ZM
VECTOR
Can be changed: C2
Data type: Unsigned16
P-Group: Encoder
Min
0 [mm]
Description:
Sets the distance between two zero marks for a linear encoder. This information is used for zero mark monitoring.
Note:
For distance-coded zero marks, this means the basic distance.
p0425[0...n]
Encoder, rotary zero mark distance / Enc rot dist ZM
VECTOR
Can be changed: C2
Data type: Unsigned32
P-Group: Encoder
Min
0
Description:
Sets the distance in pulses between two zero marks for a rotary encoder. This information is used for zero mark
monitoring.
Note:
For distance-coded zero marks, this means the basic distance.
1-86
Data set: EDS
Units group: -
Max
65535
Data set: EDS
Units group: LENGTH_M9
Max
4294967295 [nm]
Data set: EDS
Units group: -
Max
1073741823
Data set: EDS
Units group: LENGTH_M3
Max
65535 [mm]
Data set: EDS
Units group: -
Max
16777215
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Access level: 3
Function diagram: 4704,
6004
Unit selection: -
Factory setting
4096
Access level: 3
Function diagram: 4704,
6004
Unit selection: -
Factory setting
8192 [nm]
Access level: 3
Function diagram: 4704,
6004
Unit selection: -
Factory setting
8192
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
20 [mm]
Access level: 3
Function diagram: 4704,
6004, 8570
Unit selection: -
Factory setting
2048

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents