Siemens SINAMICS G List Manual page 154

Table of Contents

Advertisement

Parameters
Parameter list
p1155[0...n]
CI: Speed controller speed setpoint 1 / n_ctrl n_set 1
VECTOR
Can be changed: T
Data type: Unsigned32
P-Group: Setpoints
Min
-
Description:
Sets the signal source for the speed/velocity setpoint 1 of the speed/velocity controller.
Dependency:
The effectiveness of this setpoint depends on, e.g. STW1.4 and STW1.6.
Refer to: r0898, p1140, p1142, p1160, r1170
p1160[0...n]
CI: Speed controller speed setpoint 2 / n_ctrl n_set 2
VECTOR
Can be changed: T
Data type: Unsigned32
P-Group: Setpoints
Min
-
Description:
Sets the signal source for the speed/velocity setpoint 2 of the speed/velocity controller.
Dependency:
Refer to: p1155, r1170
r1169
CO: Speed controller, speed setpoints 1 and 2 / n_ctrl n_set 1/2
VECTOR
Can be changed: -
Data type: Floating Point
P-Group: Setpoints
Min
- [1/min]
Description:
Displays the speed/velocity setpoint after the addition of the speed/velocity setpoint 1 (p1155) and the speed/veloc-
ity setpoint 2 (p1160).
Dependency:
Refer to: p1155, p1160
r1170
CO: Speed controller, setpoint sum / n_ctr setp sum
VECTOR
Can be changed: -
Data type: Floating Point
P-Group: Setpoints
Min
- [1/min]
Description:
Displays the speed/velocity setpoint after selecting the ramp-function generator and adding the speed/velocity set-
point 1 (p1155) and speed/velocity setpoint 2 (p1160).
Dependency:
Refer to: r1150, p1155, p1160
p1189[0...n]
Speed setpoint configuration / n_ctrl config
VECTOR
Can be changed: U, T
Data type: Unsigned16
P-Group: Control
Min
0000 bin
Description:
Sets the configuration for the speed/velocity setpoint.
1-154
Data set: CDS
Units group: -
Max
-
Data set: CDS
Units group: -
Max
-
Data set: -
Units group: SPEED_ROT
Max
- [1/min]
Data set: -
Units group: SPEED_ROT
Max
- [1/min]
Data set: DDS
Units group: -
Max
0011 bin
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Access level: 3
Function diagram: 1550,
3080
Unit selection: -
Factory setting
0
Access level: 3
Function diagram: 1550,
3080
Unit selection: -
Factory setting
0
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
- [1/min]
Access level: 3
Function diagram: 1550,
1590, 3080, 5020
Unit selection: -
Factory setting
- [1/min]
Access level: 2
Function diagram: 3080
Unit selection: -
Factory setting
0011 bin