Siemens SINAMICS G List Manual page 103

Table of Contents

Advertisement

p0625[0...n]
Motor ambient temperature / Mot T_ambient
VECTOR
Can be changed: C2, U, T
Data type: Floating Point
P-Group: Motor
Min
-40 [°C]
Description:
Defines the ambient temperature of the motor to calculate the temperature model.
Note:
The parameters for stator and rotor resistance (p0350, p0354) refer to this temperature.
p0626[0...n]
Motor overtemperature, stator core / Mot T_over core
VECTOR
Can be changed: C2, U, T
Data type: Floating Point
P-Group: Motor
Min
20 [K]
Description:
Defines the rated overtemperature of the stator core referred to the ambient temperature.
Dependency:
Refer to: p0625
p0627[0...n]
Motor overtemperature, stator winding / Mot T_over stator
VECTOR
Can be changed: C2, U, T
Data type: Floating Point
P-Group: Motor
Min
20 [K]
Description:
Defines the rated overtemperature of the stator winding referred to the ambient temperature.
Dependency:
Refer to: p0625
p0628[0...n]
Rotor winding overtemperature / Mot T_over rotor
VECTOR
Can be changed: C2, U, T
Data type: Floating Point
P-Group: Motor
Min
20 [K]
Description:
Defines the rated overtemperature of the squirrel cage rotor referred to ambient temperature.
Dependency:
Refer to: p0625
r0630[0...n]
Motor temperature model ambient temperature / MotTMod T_amb.
VECTOR
Can be changed: -
Data type: Floating Point
P-Group: Motor
Min
- [°C]
Description:
Displays the ambient temperature of the motor temperature model.
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Data set: MDS
Units group: TEMPERATURE
Max
80 [°C]
Data set: MDS
Units group: TEMPERATURE_K
Max
200 [K]
Data set: MDS
Units group: TEMPERATURE_K
Max
200 [K]
Data set: MDS
Units group: TEMPERATURE_K
Max
200 [K]
Data set: MDS
Units group: TEMPERATURE
Max
- [°C]
Parameters
Parameter list
Access level: 3
Function diagram: 8016
Unit selection: -
Factory setting
20 [°C]
Access level: 3
Function diagram: 8016
Unit selection: -
Factory setting
50 [K]
Access level: 3
Function diagram: 8016
Unit selection: -
Factory setting
80 [K]
Access level: 3
Function diagram: 8016
Unit selection: -
Factory setting
100 [K]
Access level: 4
Function diagram: 8016
Unit selection: -
Factory setting
- [°C]
1-103

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents