Siemens SINAMICS G List Manual page 309

Table of Contents

Advertisement

p4099[0...2]
TM31 inputs/outputs, sampling time / TM31 I/O t_sample
TM31
Can be changed: C1
Data type: Floating Point
P-Group: Commands
Min
0.00 [µs]
Description:
Sets the sampling time for the inputs and outputs of terminal module 31 (TM31).
Index:
[0] = Digital inputs/outputs
[1] = Analog inputs
[2] = Analog outputs
Dependency:
The parameter can only be modified for p0009 = 3, 29.
The sampling times can only be set as an integer multiple of the basic sampling time (p0110, p0111).
Refer to: p0009, p0110, p0111
Notice:
The sampling times entered in index 0 (digital inputs/outputs) and index 2 (analog outputs) must always be greater
than or equal to the sampling time in index 1 (analog inputs).
Note:
The modified sampling time is not effective until the drive unit is powered-up again.
p4100
TM31 temperature evaluation, sensor type / TM31 temp sens_typ
TM31
Can be changed: T
Data type: Integer16
P-Group: -
Min
0
Description:
Sets the temperature evaluation of terminal module 31 (TM31).
This means that the temperature sensor type is selected and the evaluation is switched-in.
Values:
0:
1:
2:
Note:
The temperature sensor is connected at terminals X522.7(+) and X522.8(-).
r4101
TM31 temperature evaluation, sensor resistance / TM31 temp R_sensor
TM31
Can be changed: -
Data type: Unsigned16
P-Group: Terminals
Min
- [Ohm]
Description:
Displays the actual resistance value of the temperature sensor connected at terminal module 31 (TM31).
Note:
The temperature sensor is connected at terminals X522.7(+) and X522.8(-).
The maximum measurable resistance value is approx. 1700 Ohm.
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Evaluation disabled
PTC thermistor
KTY84
Data set: -
Units group: TIME_M6
Max
5000.00 [µs]
Data set: -
Units group: -
Max
2
Data set: -
Units group: RESISTANCE
Max
- [Ohm]
Parameters
Parameter list
Access level: 4
Function diagram: 9550
Unit selection: -
Factory setting
4000.00 [µs]
Access level: 1
Function diagram: 9576,
9577
Unit selection: -
Factory setting
0
Access level: 3
Function diagram: 9576,
9577
Unit selection: -
Factory setting
- [Ohm]
1-309