Parameters
Parameter list
p0328[0...n]
PE spindle, reluctance torque constant / Mot kT_reluctance
VECTOR
Can be changed: C2, U, T
Data type: Floating Point
P-Group: Motor
Min
0.00 [mH]
Description:
Sets the reluctance torque constant for synchronous motors with reluctance torque (e.g. 1FE ... motors).
This parameter has no significance for induction motors.
Note:
For synchronous motors without reluctance torque, the value 0 must be set.
The parameter is automatically preset for motors from the motor list (p0301).
r0330[0...n]
Rated motor slip / Mot slip_rated
VECTOR
Can be changed: -
Data type: Floating Point
P-Group: Motor
Min
- [Hz]
Description:
Displays the rated motor slip.
Dependency:
The rated slip is calculated from the rated frequency, rated speed and number of pole pairs.
Refer to: p0310, p0311, r0313
Note:
The parameter is not used for synchronous motors (p0300 = 2xx).
r0331[0...n]
Motor magnetizing current/short-circuit current (actual) / Mot I_mag_ratedAct
VECTOR
Can be changed: -
Data type: Floating Point
P-Group: Motor
Min
- [Aeff]
Description:
Induction motor:
Displays the rated magnetizing current from p0320.
For p0320 = 0, the internally calculated magnetizing current is displayed.
Synchronous motor:
Displays the rated shirt-circuit current from p0320.
Dependency:
If p0320 was not entered, then the parameter is calculated from the rating plate parameters.
r0332[0...n]
Rated motor power factor / Mot CosPhi_rated
VECTOR
Can be changed: -
Data type: Floating Point
P-Group: Motor
Min
-
Description:
Displays the rated power factor for induction motors.
For IEC motors, the following applies (p0100 = 0):
For p0308 = 0, the internally-calculated power factor is displayed.
For p0308 > 0, this value is displayed.
For NEMA motors, the following applies (p0100 = 1):
For p0309 = 0, the internally-calculated power factor is displayed.
For p0309 > 0, this value is converted into the power factor and displayed.
Dependency:
If p0308 is not entered, the parameter is calculated from the rating plate parameters.
1-70
Data set: MDS
Units group: INDUCTANCE_M3
Max
1000.00 [mH]
Data set: MDS
Units group: FREQUENCY
Max
- [Hz]
Data set: MDS
Units group: CURRENT_AC_EFF Unit selection: -
Max
- [Aeff]
Data set: MDS
Units group: -
Max
-
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
0.00 [mH]
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
- [Hz]
Access level: 3
Function diagram: 5722,
6722, 6724
Factory setting
- [Aeff]
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
-