p4083[0...1]
TB30 analog outputs, offset / TB30 AO offset
TB30
Can be changed: U, T
Data type: Floating Point
P-Group: Terminals
Min
-10.000
Description:
Sets the offset for the analog outputs of terminal board 30 (TB30).
The offset is added to the output signal after the normalization characteristic.
Index:
[0] = AO 0 (X482.5/X482.6)
[1] = AO 1 (X482.7/X482.8)
p4083[0...1]
TM31 analog outputs, offset / TM31 AO offset
TM31
Can be changed: U, T
Data type: Floating Point
P-Group: Terminals
Min
-20.000
Description:
Sets the offset for the analog outputs of terminal module 31 (TM31).
The offset is added to the output signal after the normalization characteristic.
Index:
[0] = AO 0 (X522.1, X522.2, X522.3)
[1] = AO 1 (X522.4, X522.5, X522.6)
Dependency:
The units of this parameter (V or mA) depend on the analog input type.
Refer to: p4076
Note:
This means, for example, the offset of a downstream isolating amplifier can be compensated.
p4095
TB30 digital inputs, simulation mode / TB30 DI sim_mode
TB30
Can be changed: U, T
Data type: Unsigned32
P-Group: Commands
Min
0000 bin
Description:
Sets the simulation mode for the digital inputs of the terminal board 30 (TB30).
Bit field:
Bit
Signal name
00
DI 0 (X481.1)
01
DI 1 (X481.2)
02
DI 2 (X481.3)
03
DI 3 (X481.4)
Dependency:
The setpoint for the input signals is specified using p4096.
Refer to: p4096
Note:
DI: Digital input
This parameter is not saved when data is backed-up (p0971, p0977).
p4095
TM31 digital inputs, simulation mode / TM31 DI sim_mode
TM31
Can be changed: U, T
Data type: Unsigned32
P-Group: Terminals
Min
0000 bin
Description:
Sets the simulation mode for the digital inputs of terminal module 31 (TM31).
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Data set: -
Units group: -
Max
10.000
Data set: -
Units group: -
Max
20.000
Data set: -
Units group: -
Max
1111 bin
0 signal
Terminal eval.
Terminal eval.
Terminal eval.
Terminal eval.
Data set: -
Units group: -
Max
0000 1111 1111 1111 bin
Parameters
Parameter list
Access level: 1
Function diagram: 9106
Unit selection: -
Factory setting
0.000
Access level: 1
Function diagram: 9572
Unit selection: -
Factory setting
0.000
Access level: 2
Function diagram: 1790,
9100
Unit selection: -
Factory setting
0000 bin
1 signal
FP
Simulation
-
Simulation
-
Simulation
-
Simulation
-
Access level: 2
Function diagram: 1840,
9550, 9552, 9560, 9562
Unit selection: -
Factory setting
0000 bin
1-305

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents