Parameters
Parameter list
p1750[0...n]
Motor model configuration / MotMod config
VECTOR (n/M)
Can be changed: U, T
Data type: Unsigned8
P-Group: Control
Min
0000 bin
Description:
Sets the configuration of the motor model.
Bit field:
Bit
Signal name
00
Controlled start
01
Controlled through 0 Hz
02
Set motor model
r1751
Motor model status / MotMod status
VECTOR (n/M)
Can be changed: -
Data type: Unsigned16
P-Group: Control
Min
-
Description:
Displays the status of the motor model.
Bit field:
Bit
Signal name
00
Controlled operation
01
Set ramp-function generator
02
Stop RsLh adaptation
03
Feedback
04
Encoder operation
05
Holding angle
06
Acceleration criteria
12
Rs adaptation waits
13
Motor operation
14
Stator frequency sign
15
Torque sign
p1752[0...n]
Motor model changeover speed operation with encoder / MotMod n_chgov enc
VECTOR (n/M)
Can be changed: U, T
Data type: Floating Point
P-Group: Control
Min
0.0 [1/min]
Description:
Sets the speed/velocity to change over the motor model for operation with encoder.
Dependency:
Refer to: p1756
p1755[0...n]
Motor model changeover speed sensorless operation / MotMod n_chgSnsorl
VECTOR (n/M)
Can be changed: U, T
Data type: Floating Point
P-Group: Control
Min
0.0 [1/min]
Description:
Sets the speed/velocity to change over the motor model to sensorless operation (without encoder).
Dependency:
Refer to: p1756
Note:
The changeover speed applies for the changeover between open-loop and closed-loop control mode.
1-210
Data set: DDS
Units group: -
Max
0111 bin
0 signal
No
No
No
Data set: -
Units group: -
Max
-
0 signal
not active
not active
No
not active
not active
No
not active
No
No
Negative
Regenerative mode
Data set: DDS
Units group: SPEED_ROT
Max
210000.0 [1/min]
Data set: DDS
Units group: SPEED_ROT
Max
210000.0 [1/min]
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
0000 bin
1 signal
FP
Yes
-
Yes
-
Yes
-
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
-
1 signal
FP
active
-
active
-
Yes
-
active
-
active
-
Yes
-
active
-
Yes
-
Yes
-
Positive
-
Motor mode
-
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
210000.0 [1/min]
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
210000.0 [1/min]