p0186[0...n]
Motor data sets (MDS) number / MDS number
VECTOR
Can be changed: C1
Data type: Unsigned8
P-Group: Data sets
Min
0
Description:
Using the parameter, each drive data set (= index) is assigned the associated motor data set (MDS).
The parameter value therefore corresponds to the number of the assigned motor data set.
Dependency:
This parameter is only relevant for servo and vector drives (see p0107).
Note:
For servo and vector drives:
The data set basic commissioning can only be exited if all of the drive data sets are assigned an existing motor
parameter data set.
A value of 99 means that no encoder has been assigned to this drive data set (not configured).
p0187[0...n]
Encoder 1 encoder data set number / Enc 1 EDS number
VECTOR
Can be changed: C1
Data type: Unsigned8
P-Group: Data sets
Min
0
Description:
Using the parameter, each drive data set (= index) is assigned the associated encoder data (EDS) for encoder 1.
The parameter value therefore corresponds to the number of the assigned encoder data set.
Example:
Encoder data set 0 should be assigned to encoder 1 in drive data set 2.
--> p0187[2] = 0
Note:
A value of 99 means that no encoder has been assigned to this drive data set (not configured).
The same value must be entered for all of the indices.
p0188[0...n]
Encoder 2 encoder data set number / Enc 2 EDS number
VECTOR
Can be changed: C1
Data type: Unsigned8
P-Group: Data sets
Min
0
Description:
Using the parameter, each drive data set (= index) is assigned the associated encoder data (EDS) for encoder 2.
The parameter value therefore corresponds to the number of the assigned encoder data set.
Note:
A value of 99 means that no encoder has been assigned to this drive data set (not configured).
The same value must be entered for all of the indices.
p0189[0...n]
Encoder 3 encoder data set number / Enc 3 EDS number
VECTOR
Can be changed: C1
Data type: Unsigned8
P-Group: Data sets
Min
0
Description:
Using the parameter, each drive data set (= index) is assigned the associated encoder data (EDS) for encoder 3.
The parameter value therefore corresponds to the number of the assigned encoder data set.
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Data set: DDS
Units group: -
Max
99
Data set: DDS
Units group: -
Max
99
Data set: DDS
Units group: -
Max
99
Data set: DDS
Units group: -
Max
99
Parameters
Parameter list
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
0
Access level: 3
Function diagram: 1580,
8570
Unit selection: -
Factory setting
99
Access level: 3
Function diagram: 1580,
8570
Unit selection: -
Factory setting
99
Access level: 3
Function diagram: 1580,
8570
Unit selection: -
Factory setting
99
1-55