Parameters
Parameter list
p1500[0...n]
Macro connector inputs (CI) for torque setpoints / Macro CI M_set
VECTOR
Can be changed: C2, T
Data type: Unsigned32
P-Group: Commands
Min
0
Description:
Runs the appropriate ACX file on the CompactFlash Card.
The connector inputs (CI) for the torque setpoints of the appropriate command data set (CDS) are appropriately
interconnected.
The selected ACX file must be located in the following directory:
... /PMACRO/<drive object>/P1500/PMxxxxxx.ACX
Example:
p1500 = 6 --> the file PM000006.ACX is run.
Dependency:
The ACX file to be run must be created according to the definition for ACX macros and must be saved in the direc-
tory intended on the CompactFlash Card.
Refer to: p0015, p0700, p1000
Note:
CI: Connector input
p1501[0...n]
BI: Change over between closed-loop speed/torque control / Changeov n/M_ctrl
VECTOR (n/M)
Can be changed: U, T
Data type: Unsigned32
P-Group: Control
Min
-
Description:
Sets the signal source for toggling between speed and torque control.
Dependency:
The input connectors to enter the torque are provided using p1511, p1512 and p1513.
Refer to: p1300
Cautiont:
If the closed-loop torque control is activated (p1300) and a change is made to closed-loop torque control (p1501),
OFF1 (p0840) does not have its own braking response but pulse cancellation when standstill is detected (p1226,
p1227).
Note:
1 signal: Speed control
0 signal: Torque Control
p1503[0...n]
CI: Torque setpoint / M_set
VECTOR (n/M)
Can be changed: T
Data type: Unsigned32
P-Group: Control
Min
-
Description:
Sets the signal source for the torque setpoint for torque control.
Note:
A change is made to closed-loop torque control if, in p1300, closed-loop torque control was selected or if the selec-
tion was made using the changeover source in p1501.
it is also possible to change over in operation using p1501.
1-192
Data set: CDS
Units group: -
Max
999999
Data set: CDS
Units group: -
Max
-
Data set: CDS
Units group: -
Max
-
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Access level: 1
Function diagram: -
Unit selection: -
Factory setting
0
Access level: 3
Function diagram: 2520,
5060, 6060
Unit selection: -
Factory setting
0
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
0