Siemens SINAMICS G List Manual page 273

Table of Contents

Advertisement

p2210[0...n]
CO: Technology controller, fixed value 10 / Tec_ctr fix val 10
VECTOR (Tech ctrl) Can be changed: U, T
Data type: Floating Point
P-Group: Technology
Min
-200.00 [%]
Description:
Sets the value for fixed value 10 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
p2211[0...n]
CO: Technology controller, fixed value 11 / Tec_ctr fix val 11
VECTOR (Tech ctrl) Can be changed: U, T
Data type: Floating Point
P-Group: Technology
Min
-200.00 [%]
Description:
Sets the value for fixed value 11 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
p2212[0...n]
CO: Technology controller, fixed value 12 / Tec_ctr fix val 12
VECTOR (Tech ctrl) Can be changed: U, T
Data type: Floating Point
P-Group: Technology
Min
-200.00 [%]
Description:
Sets the value for fixed value 12 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
p2213[0...n]
CO: Technology controller, fixed value 13 / Tec_ctr fix val 13
VECTOR (Tech ctrl) Can be changed: U, T
Data type: Floating Point
P-Group: Technology
Min
-200.00 [%]
Description:
Sets the value for fixed value 13 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
p2214[0...n]
CO: Technology controller, fixed value 14 / Tec_ctr fix val 14
VECTOR (Tech ctrl) Can be changed: U, T
Data type: Floating Point
P-Group: Technology
Min
-200.00 [%]
Description:
Sets the value for fixed value 14 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Data set: DDS
Units group: PERCENT
Max
200.00 [%]
Data set: DDS
Units group: PERCENT
Max
200.00 [%]
Data set: DDS
Units group: PERCENT
Max
200.00 [%]
Data set: DDS
Units group: PERCENT
Max
200.00 [%]
Data set: DDS
Units group: PERCENT
Max
200.00 [%]
Parameters
Parameter list
Access level: 2
Function diagram: 7950
Unit selection: -
Factory setting
90.00 [%]
Access level: 2
Function diagram: 7950
Unit selection: -
Factory setting
100.00 [%]
Access level: 2
Function diagram: 7950
Unit selection: -
Factory setting
110.00 [%]
Access level: 2
Function diagram: 7950
Unit selection: -
Factory setting
120.00 [%]
Access level: 2
Function diagram: 7950
Unit selection: -
Factory setting
130.00 [%]
1-273

Hide quick links:

Advertisement

Table of Contents
loading