p0408[0...n]
Rotary encoder pulse No. / Encoder pulse No.
VECTOR
Can be changed: C2
Data type: Unsigned32
P-Group: Encoder
Min
0
Description:
Sets the number of pulses for a rotary encoder.
Note:
The number of pole pairs for a resolver is entered here.
The smallest permissible value is 1 pulse.
p0410[0...n]
Encoder inversion actual value / Enc inv act value
VECTOR
Can be changed: T
Data type: Unsigned16
P-Group: Encoder
Min
0000 bin
Description:
Setting to invert actual values.
Bit field:
Bit
Signal name
00
Invert speed actual value
01
Invert position actual value
Note:
The inversion influences the following parameters:
Bit 00: r0061, r0063 (exception: sensorless closed-loop control), r0094
Bit 01: r0482, r0483
p0418[0...n]
Fine resolution Gx_XIST1 (in bits) / Enc fine Gx_XIST1
VECTOR
Can be changed: C2
Data type: Unsigned8
P-Group: Encoder
Min
2
Description:
Sets the fine resolution in bits of incremental position actual values for the PROFIBUS encoder interface.
Note:
The parameter applies for the following process data:
- Gx_XIST1
- Gx_XIST2 for reference mark or flying measurement
p0419[0...n]
Fine resolution absolute value Gx_XIST2 (in bits) / Enc fine Gx_XIST2
VECTOR
Can be changed: C2
Data type: Unsigned8
P-Group: Encoder
Min
2
Description:
Sets the fine resolution in bits of absolute position actual values for the PROFIBUS encoder interface.
Note:
This parameter applies to process data Gx_XIST2 when reading the absolute value.
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Data set: EDS
Units group: -
Max
16777215
Data set: EDS
Units group: -
Max
0011 bin
0 signal
No
No
Data set: EDS
Units group: -
Max
18
Data set: EDS
Units group: -
Max
18
Parameters
Parameter list
Access level: 3
Function diagram: 4704,
6004
Unit selection: -
Factory setting
2048
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
0000 bin
1 signal
FP
Yes
4710,
6010
Yes
4704
Access level: 3
Function diagram: 4704
Unit selection: -
Factory setting
11
Access level: 3
Function diagram: 4704
Unit selection: -
Factory setting
9
1-85