Parameters
Parameter list
r2145[0...7]
Alarm time received in days / t_alarm recv days
All objects
Can be changed: -
Data type: Unsigned16
P-Group: Messages
Min
-
Description:
Displays the system runtime in days when the alarm occurred.
Dependency:
Refer to: r2110, r2114, r2122, r2123, r2124, r2125, r2134, r2146
r2146[0...7]
Alarm time removed in days / t_alarm res days
All objects
Can be changed: -
Data type: Unsigned16
P-Group: Messages
Min
-
Description:
Displays the system runtime in days when the alarm was cleared.
Dependency:
Refer to: r2110, r2114, r2122, r2123, r2124, r2125, r2134, r2145
p2147
Delete fault buffer of all drive objects / Del fault buffer
CU
Can be changed: U, T
Data type: Integer16
P-Group: Displays, signals
Min
0
Description:
Is used to delete (clear) the fault buffer of all of the existing drive objects.
Values:
0:
1:
Dependency:
Refer to: r0945, r0947, r0948, r0949, r2109, r2130, r2133, r2136
Note:
p2147 is automatically set to 0 after execution.
p2148[0...n]
BI: Ramp-function generator active / HLG active
VECTOR
Can be changed: U, T
Data type: Unsigned32
P-Group: Messages
Min
-
Description:
Sets the signal source for the signal "ramp-function generator active" for the following signals/messages:
"Speed setpoint - actual value deviation within tolerance t_on" (BO: r2199.4)
Ramp-up/ramp-down completed (BO: r2199.5)
Note:
The binector input is automatically pre-assigned to r1199.2.
The following applies for SERVO:
The pre-assignment is only made when the function module "setpoint channel" is activated (r0108.8 = 1).
1-262
not active
Start to delete the fault buffer of all drive objects
Data set: -
Units group: -
Max
-
Data set: -
Units group: -
Max
-
Data set: -
Units group: -
Max
1
Data set: CDS
Units group: -
Max
-
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Access level: 3
Function diagram: 8065
Unit selection: -
Factory setting
-
Access level: 3
Function diagram: 8065
Unit selection: -
Factory setting
-
Access level: 4
Function diagram: 8060
Unit selection: -
Factory setting
0
Access level: 3
Function diagram: 8010
Unit selection: -
Factory setting
0