F07841
Drive: Infeed operation withdrawn
Reaction:
OFF2 (NONE, OFF1, OFF3)
Acknowledge:
IMMEDIATELY
Cause:
The signal "infeed operation" was withdrawn in operation.
- interconnection of the binector input for the signal "infeed operation" is either incorrect or missing (p0864).
- the enable signals of the infeed were disabled.
- due to a fault, the infeed withdraws the signal "infeed operation".
Remedy:
- check the interconnection of the binector input for the signal "infeed operation" (p0864).
- check the enable signals of the infeed and if required, enable.
- remove and acknowledge an infeed fault.
Note:
If this drive is intended to back-up the DC link regeneratively, then the fault response must be parameterized for
NONE so that the drive can continue to operate even after the infeed fails.
A07850 (F)
External alarm 1
Reaction:
NONE
Acknowledge:
NONE
Cause:
BICO signal "external alarm" triggered. The condition for this external alarm is fulfilled.
See also: p2112
Remedy:
Eliminate the causes of this alarm.
Reaction upon F:
NONE (DCBRAKE, OFF1, OFF2, OFF3, STOP1, STOP2)
Acknowledge
IMMEDIATELY (power on)
upon F:
A07851 (F)
External alarm 2
Reaction:
NONE
Acknowledge:
NONE
Cause:
BICO signal "external alarm" triggered. The condition for this external alarm is fulfilled.
See also: p2116
Remedy:
Eliminate the causes of this alarm.
Reaction upon F:
NONE (DCBRAKE, OFF1, OFF2, OFF3, STOP1, STOP2)
Acknowledge
IMMEDIATELY (power on)
upon F:
A07852 (F)
External alarm 3
Reaction:
NONE
Acknowledge:
NONE
Cause:
BICO signal "external alarm" triggered. The condition for this external alarm is fulfilled.
See also: p2117
Remedy:
Eliminate the causes of this alarm.
Reaction upon F:
NONE (DCBRAKE, OFF1, OFF2, OFF3, STOP1, STOP2)
Acknowledge
IMMEDIATELY (power on)
upon F:
F07860 (A)
External fault 1
Reaction:
OFF2 (DCBRAKE, NONE, OFF1, OFF3, STOP1, STOP2)
Acknowledge:
IMMEDIATELY (power on)
Cause:
BICO signal "external alarm" triggered.
See also: p2106
Remedy:
Eliminate the causes of this fault.
Reaction upon A:
NONE
Acknowledge
NONE
upon A: