Siemens SINAMICS G List Manual page 298

Table of Contents

Advertisement

Parameters
Parameter list
p4067[0...1]
BI: TB30 analog inputs, signal source for inversion / TB30 AI invert
TB30
Can be changed: U, T
Data type: Unsigned32
P-Group: Terminals
Min
-
Description:
Sets the signal source to invert the analog input signals of the terminal board 30 (TB30).
Index:
[0] = AI 0 (X482.1/X482.2)
[1] = AI 1 (X482.3/X482.4)
p4067[0...1]
BI: TM31 analog inputs, signal source for inversion / TM31 AI invert
TM31
Can be changed: U, T
Data type: Unsigned32
P-Group: Terminals
Min
-
Description:
Sets the signal source to invert the analog inputs signals of terminal module 31 (TM31).
Index:
[0] = AI 0 (X521.1/X521.2, S5.0)
[1] = AI 1 (X521.3/X521.4, S5.1)
p4068[0...1]
TB30 analog inputs, window to suppress noise / TB30 AI window
TB30
Can be changed: U, T
Data type: Floating Point
P-Group: Terminals
Min
0.00 [%]
Description:
Sets the noise suppression window for the analog inputs of terminal board 30 (TB30).
Changes less than the window are suppressed.
Index:
[0] = AI 0 (X482.1/X482.2)
[1] = AI 1 (X482.3/X482.4)
p4068[0...1]
TM31 analog inputs, window to suppress noise / TM31 AI window
TM31
Can be changed: U, T
Data type: Floating Point
P-Group: Terminals
Min
0.00 [%]
Description:
Sets the window for noise suppression for the analog inputs of terminal module 31 (TB31).
Changes less than the window are suppressed.
Index:
[0] = AI 0 (X521.1/X521.2, S5.0)
[1] = AI 1 (X521.3/X521.4, S5.1)
p4069[0...1]
BI: TB30 analog inputs, signal source for enable / TB30 AI enable
TB30
Can be changed: U, T
Data type: Unsigned32
P-Group: Terminals
Min
-
Description:
Sets the signal source for enabling the analog inputs of the terminal board 30 (TB30).
1-298
Data set: -
Units group: -
Max
-
Data set: -
Units group: -
Max
-
Data set: -
Units group: PERCENT
Max
20.00 [%]
Data set: -
Units group: PERCENT
Max
20.00 [%]
Data set: -
Units group: -
Max
-
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Access level: 3
Function diagram: 9104
Unit selection: -
Factory setting
0
Access level: 3
Function diagram: 9566,
9568
Unit selection: -
Factory setting
0
Access level: 3
Function diagram: 9104
Unit selection: -
Factory setting
0.00 [%]
Access level: 3
Function diagram: 9566,
9568
Unit selection: -
Factory setting
0.00 [%]
Access level: 3
Function diagram: 9104
Unit selection: -
Factory setting
1